Skip navigation to main content
United States Department of Transportation - Federal Highway Administration FHWA Homefeedback

4.0 Geometric and Safety Design

4.8.3 Recommended Guidelines

Lighting Design Issues

According to the AASHTO “Green Book”, where there are concentrations of pedestrians and roadside intersectional interferences, fixed-source lighting tends to reduce crashes. The “Green Book” does mention that toll plazas are usually lighted. Due to the amount of activity from traffic weaving, diverging, merging and stopping in the approach and departure zones, and the presence of fixed objects mounted in front of and to the toll island(s) adjacent to the toll lane, properly designed luminaries are critical to maintaining safety and operational efficiency through the plaza.

Some of the significant issues that should be addressed when designing toll plaza lighting include the following:

Lighting Guidelines

Guideline Lighting Design Guideline 1
Title Intensity and Uniform Coverage
Text Intensity levels and uniformity ratios should be based on adaptations from the American National Standards Institute (ANSI) and Illuminating Engineering Society (IES).
Commentary None

 

Guideline Lighting Design Guideline 2
Title Minimize Lighting Spillover
Text Use proper shielding and aiming to minimize lighting spillover into adjacent properties, especially residential communities.
Commentary Migration of light pollution should be in accordance with approved environmental document(s).

 

Guideline Lighting Design Guideline 3
Title Quantity of Plaza Approach and Departure Lights
Text High mast and tower pole designs for mounting luminaries should be used to minimize the addition of roadway hazards that must be protected by barrier if inadequate clear zone is available or is impractical.
Commentary Tower design must address the issue of accessing the luminaries for maintenance.

 

Guideline Lighting Design Guideline 4
Title Toll Lane Lighting
Text Lighting intensity and uniformity should be based on adaptations from the American National Standards Institute (ANSI) and Illuminating Engineering Society (IES).
Commentary Toll lane lighting should provide a minimum of 20 foot-candles, subject to consideration of contributions from other site-specific light sources.


Table of Contents | List of Tables | List of Figures | Previous Section | Next Section | HOME


FHWA Home | U.S. DOT | Operations Home | Privacy Policy
fhwa
Federal Highway Administration - United States Department of Transportation