empty cell
Manual on Uniform Traffic Control Devices (MUTCD) arrows logo

Full-size image of Figure 4D-1

Figure 4D-1. Maximum Mounting Height of Signal Faces Located Between 12 Meters (40 Feet) and 16 Meters (53 Feet) from Stop Line

This figure shows the maximum mounting height to the top of the signal housing above the pavement, in both meters and feet, for signal faces located between 12 meters (40 feet) and 16 meters (53 feet) from the stop line, as described in Section 4D.15.

Meters Feet
Horizontal Distance from Stop Line Height to Top of Signal Housing Above Pavement Horizontal Distance from Stop Line Height to Top of Signal Housing Above Pavement
12.0
6.4
40.0
21.0
12.5
6.56
41.0
21.3
13.0
6.75
42.0
21.7
13.5
6.93
43.0
22.1
14.0
7.1
44.0
22.4
14.5
7.26
45.0
22.7
15.0
7.44
46.0
23.2
15.5
7.6
47.0
23.5
16.0
7.8
48.0
23.8
Not applicable
Not applicable
49.0
24.2
Not applicable
Not applicable
50.0
24.5
Not applicable
Not applicable
51.0
24.9
Not applicable
Not applicable
52.0
25.3
Not applicable
Not applicable
53.0
25.6

Back to Chapter 4D